2005- Entellisys Introduced October 2005 as a new
platform for low voltage switchgear. Uses non-
automatic EntelliGuard
present breakers (similar to WavePro except no current
sensors, no trip unit, and limited accessories).
Entellisys uses redundant
components for highest reliability and maximum up-
time. Redundant CPU’s perform all protection,
metering, control,
and monitoring functions. Other redundant components
of the system include 2 UPS’s, 2 network
communication
switches for internal communication, 2 control power
throwover relays, 2 control power sources (120vAC).
Each breaker
cubicle is provided with an EntelliGuard Messenger,
which is the interface between the CPU’s and the
circuit breaker
operating mechanisms. The Messenger performs A/D and
D/A conversions plus provides back-up overcurrent
proteciton
for the breaker if all control power and
communications are lost.
Equipment construction is the same as AKD-10
switchgear (frame, bussing, drawout cubicles, etc).
Entellisys does
not replace AKD-10. Both product lines are currently
being produced.
2
Switchgear
2
Prices and data subject Aftermarket Catalog
www.geelectrical.com 2-3
to change without notice
Low Voltage Power and DC Circuit Breakers
Gerapid High Speed DC Circuit Breakers
Technical Data for Rectifier Circuit Breaker Models
8007R and 10007R
Breaker type Gerapid 8007R Gerapid 1007R
Arc chute type 1x2 1x3 1x2 1x3
Rated current In/A 6,000 6,000 8,000 8,000
Rated operating voltage Ue/V 800 1,200 800 1,200
Rated insulation voltage Ui/V 2,000 2,000 2,000 2,000
120 min./A 7,200 7,200 9,600 9,600
Short time current 2 min./A 8,000 8,000 16,000 16,000
20 sec./A 12,000 12,000 24,000 24,000
Mechanical endurance ops. 10,0001 10,0001 10,0001
10,0001
Total weight approx. kg 220 220 220 220
1With regular maintenance 100,000 ops.
Figure 3. Gerapid 8007R and 10007R Rectifier CB, 1X2
Arc Chute, 800VDC
(Dimensions in mm)
Switchgear
2
2-4 Aftermarket Catalog www.geelectrical.com Prices
and data subject
to change without notice
Low Voltage Power and DC Circuit Breakers
AK and AKR Low Voltage Power Circuit Breakers
New AK and AKR low voltage power circuit breakers are
available for replacement and
retrofill needs. The following circuit breakers are
available:
AK Circuit Breaker
AC Voltage Rating Frame Size Short-circuit Ratings —
RMS Symmetrical KA
60 Hertz Breaker Type (Amps) With Instantaneous Trip
Without Instantaneous Trip
AK-25 600 22 22
600 AK-50 1600 42 42
AK-50H 1600 65 65
AK-25 600 30 22
480 AK-50 1600 50 50
AK-50H 1600 65 65
AK-25 600 42 22
240 AK-50 1600 65 50
AK-50H 1600 85 65
AKR Circuit Breaker
AC Voltage Rating Frame Size Short-circuit Ratings —
RMS Symmetrical KA
50/60 Hertz Breaker Type (Amps) With Instantaneous
Trip Without Instantaneous Trip
AKR-30 800 30 30
AKR-30H 800 42 42
600 AKR-50 1600 42 42
AKR-50H 1600 65 65
AKRT-50H 2000 65 65
AKR-75 3200 65 65
AKR-100 4000 85 85
AKR-30 800 30 30
AKR-30H 800 42 42
480 AKR-50 1600 50 50
AKR-50H 1600 65 65
AKRT-50H 2000 65 65
AKR-75 3200 65 65
AKR-100 4000 85 85
AKR-30 800 42 30
AKR-30H 800 50 42
240 AKR-50 1600 65 50
AKR-50H 1600 65 65
AKRT-50H 2000 65 65
AKR-75 3200 85 65
AKR-100 4000 130 85
Contact your local GE sales representative for price
and delivery. Be prepared to provide full
nameplate data from your existing low voltage
switchgear lineup.
AK-25 Breaker
AKR-30H Breaker
Switchgear
2
Prices and data subject Aftermarket Catalog
www.geelectrical.com 2-5
to change without notice
AK-25 Breaker with EntelliGuard? TU Trip Unit
Low Voltage Power and DC Circuit Breakers
Trip Unit Conversion Kits
EntelliGuard? TU Conversion Kits
GE offers a complete line of trip unit upgrade kits
for low voltage
power circuit breakers manufactured by GE, as well as
by
Westinghouse, I-T-E, and Allis-Chalmers. These
conversion kits
contain everything necessary to convert an old-style
electromechanical
or solid-state trip unit to today's latest electronic,
digital technology—including the addition of
metering, protective
relay, waveform capture, RELT, and communication
functions.
All conversion kits designed by GE are tested to ANSI
C37.59
standards for each breaker type so customers have the
assurance of safe, reliable operation.
Features and Benefits–All Kits
—Kit includes everything needed in one compact
package
—Full-range of interchangeable rating plugs
—Trip targets for quick identification of overload,
short circuit,
and ground fault trips
—Sealable, see-through cover to prevent unauthorized
access to