    商品詳情
      Publication Description Stocking Location
      GEH-6263 2-high Maintenance Instructions Bloomington1
      GEH-5305 1-high Maintenance Instructions Bloomington1
      GET-6840 Selection & Application Bloomington1
      DET-064 Advertising Brochure Bloomington1
      GEH-5396 800 Amp 1-high Maintenance Bloomington1
      GEF-8016 Contactor Renewal Parts Mebane
      GEH-5306 Contactor Maintenance Instructions Bloomington1
      GES-5000 Power Fuse Curves Bloomington1
      GEP-1260 Control Catalog—Covers Full Line of Products Bloomington1
      GEA-10877 CR104P Push Buttons and Pilot Lights Bloomington1
      GEH-4115 CR120B AC Relays Bloomington1
      GEH-4120 CR120B Latched Relays Bloomington1
      GEH-6248 CR4 Control and Timing Relay Bloomington1
      CR194 Vacuum Design
      Fuses/Curves
      General Purpose Controls
      Pilot Devices
      Relays and Timers
      DEA-328 Medium Voltage Soft Starters Bloomington1
      GEH-5475 C-2000 Mini-Contactors Control Relays Bloomington1
      1601-0057 Multilin 469 GE Multilin?
      1601-0077 Multilin 369 GE Multilin?
      1601-0025 Multilin 269 GE Multilin?
      1601-0013 Multilin 269+ GE Multilin?
      1601-0060 Multilin 239+ GE Multilin?
      GEH-6302 Power Leader? EPM, User's Guide Bloomington1
      GEH-5892 Power Leader?, User's Guide Bloomington1
      1Ordering address on BuyLog? page 22-1.
      Metering
      Motor Control Centers
      3
      Prices and data subject Aftermarket Catalog www.geelectrical.com 3-17
      to change without notice
      Motor Control Centers—Medium Voltage
      Limitamp
      2400-7200 Volts
      Limitamp Product Scope
      Product/
      Application
      Max. Fault
      Rating
      Max. Current
      Rating (Amps) Main Bus Rating1 Enclosure Size2 Power Fuse
      Types
      Overload
      Relays3 Potential
      Transformers
      One High
      One High
      CR194 400A5
      5
      5
      Vacuum Stationary
      Control (FVNR)
      (induction motor or
      transformer loads
      50 kA rms sym.
      4.80 kV (fused)
      360A vented
      320A non-vented
      11
      10
      10
      10
      11
      1200A
      2000A
      3600A12
      (2800A non-vented)
      1200A & 2000A
      3600A12
      (2800A non-vented)
      1000A & 2000A
      3600A12
      (2800A non-vented)
      1000A & 2000A
      3600A12
      (2800A non-vented)
      1000A & 2000A
      3600A12
      (2800A non-vented)
      1200A8
      2000A
      (1950A non-vented)
      3600A12
      (2800A non-vented)
      1-high
      26W x 90H x 30D
      (34W optional)
      GE Type
      RB
      Bolted or Clip
      Bolted or Clip
      CR324C
      Multilin
      269+
      N/A
      Two High
      CR194 400A
      Vacuum Stationary
      or Drawout (FVNR)
      50 kA rms sym.
      7.2 kV (fused)
      TOP: 360A vented
       320A non-vented
      BOTTOM: 400A vented
       320A non-vented
      2-high
      36W x 90H x 30D
      (40W optional)
      GE Type
      RB
      CR324C
      Multilin
      269+
      N/A
      N/A
      N/A
      CR194 800A
      Vacuum Stationary
      or Drawout (FVNR)
      (induction motor or
      transformer loads)
      50 kA rms sym.
      4.80 kV (fused)
      760A vented
      640A non-vented
      1-high
      480W x 90H x 30D Type RB
      Bolted
      CR324C
      Multilin
      269+
      CR7160 400A9
      Air-Break Drawout
      (FVNR)
      (induction motor or
      transformer loads)
      50 kA rms sym.
      4.80 kV (fused)
      320A 1-high non-vented
      360A 1-high vented
      310A 2-high vented
      250A 3-high vented
      310A 3-high, with only
      2 contactors
      1-high
      34W x 90H x 30D
      (42W optional)
      2-high & 3-high
      44W x 90H x 30D
      GE
      Type RA
      or RB
      CR324C
      Multilin
      269+
      IC1074 1200A6
      Load Break Switch
      (stationary)
      (main, feeder, or tie)
      38 kA rms sym.
      4.76 kV (fused)
      1200A vented w/o fuse
      1000A non-vented w/o fuse
      960A vented with fuse
      840A non-vented with fuse
      38W x 90H x 30D Ferraz
      Shawmut
      Ferraz
      Shawmut
      N/A
      ITI
      stationary
      Auxiliary Sections7
      (incoming line,
      metering auxiliary)
      38 kA rms sym.
      4.76 kV Per devices installed
      90H x 30D
      any width available
      (22" minimum)
      N/A N/A
      ITI
      stationary
      drawout
      drawout