Publication Description Stocking Location
GEH-6263 2-high Maintenance Instructions Bloomington1
GEH-5305 1-high Maintenance Instructions Bloomington1
GET-6840 Selection & Application Bloomington1
DET-064 Advertising Brochure Bloomington1
GEH-5396 800 Amp 1-high Maintenance Bloomington1
GEF-8016 Contactor Renewal Parts Mebane
GEH-5306 Contactor Maintenance Instructions Bloomington1
GES-5000 Power Fuse Curves Bloomington1
GEP-1260 Control Catalog—Covers Full Line of Products Bloomington1
GEA-10877 CR104P Push Buttons and Pilot Lights Bloomington1
GEH-4115 CR120B AC Relays Bloomington1
GEH-4120 CR120B Latched Relays Bloomington1
GEH-6248 CR4 Control and Timing Relay Bloomington1
CR194 Vacuum Design
Fuses/Curves
General Purpose Controls
Pilot Devices
Relays and Timers
DEA-328 Medium Voltage Soft Starters Bloomington1
GEH-5475 C-2000 Mini-Contactors Control Relays Bloomington1
1601-0057 Multilin 469 GE Multilin?
1601-0077 Multilin 369 GE Multilin?
1601-0025 Multilin 269 GE Multilin?
1601-0013 Multilin 269+ GE Multilin?
1601-0060 Multilin 239+ GE Multilin?
GEH-6302 Power Leader? EPM, User's Guide Bloomington1
GEH-5892 Power Leader?, User's Guide Bloomington1
1Ordering address on BuyLog? page 22-1.
Metering
Motor Control Centers
3
Prices and data subject Aftermarket Catalog
www.geelectrical.com 3-17
to change without notice
Motor Control Centers—Medium Voltage
Limitamp
2400-7200 Volts
Limitamp Product Scope
Product/
Application
Max. Fault
Rating
Max. Current
Rating (Amps) Main Bus Rating1 Enclosure Size2 Power Fuse
Types
Overload
Relays3 Potential
Transformers
One High
One High
CR194 400A5
5
5
Vacuum Stationary
Control (FVNR)
(induction motor or
transformer loads
50 kA rms sym.
4.80 kV (fused)
360A vented
320A non-vented
11
10
10
10
11
1200A
2000A
3600A12
(2800A non-vented)
1200A & 2000A
3600A12
(2800A non-vented)
1000A & 2000A
3600A12
(2800A non-vented)
1000A & 2000A
3600A12
(2800A non-vented)
1000A & 2000A
3600A12
(2800A non-vented)
1200A8
2000A
(1950A non-vented)
3600A12
(2800A non-vented)
1-high
26W x 90H x 30D
(34W optional)
GE Type
RB
Bolted or Clip
Bolted or Clip
CR324C
Multilin
269+
N/A
Two High
CR194 400A
Vacuum Stationary
or Drawout (FVNR)
50 kA rms sym.
7.2 kV (fused)
TOP: 360A vented
320A non-vented
BOTTOM: 400A vented
320A non-vented
2-high
36W x 90H x 30D
(40W optional)
GE Type
RB
CR324C
Multilin
269+
N/A
N/A
N/A
CR194 800A
Vacuum Stationary
or Drawout (FVNR)
(induction motor or
transformer loads)
50 kA rms sym.
4.80 kV (fused)
760A vented
640A non-vented
1-high
480W x 90H x 30D Type RB
Bolted
CR324C
Multilin
269+
CR7160 400A9
Air-Break Drawout
(FVNR)
(induction motor or
transformer loads)
50 kA rms sym.
4.80 kV (fused)
320A 1-high non-vented
360A 1-high vented
310A 2-high vented
250A 3-high vented
310A 3-high, with only
2 contactors
1-high
34W x 90H x 30D
(42W optional)
2-high & 3-high
44W x 90H x 30D
GE
Type RA
or RB
CR324C
Multilin
269+
IC1074 1200A6
Load Break Switch
(stationary)
(main, feeder, or tie)
38 kA rms sym.
4.76 kV (fused)
1200A vented w/o fuse
1000A non-vented w/o fuse
960A vented with fuse
840A non-vented with fuse
38W x 90H x 30D Ferraz
Shawmut
Ferraz
Shawmut
N/A
ITI
stationary
Auxiliary Sections7
(incoming line,
metering auxiliary)
38 kA rms sym.
4.76 kV Per devices installed
90H x 30D
any width available
(22" minimum)
N/A N/A
ITI
stationary
drawout
drawout