ACCUPRO 516-902-22 專業(yè)供應(yīng)
ACCUPRO 516-902-22 專業(yè)供應(yīng)
產(chǎn)品價(jià)格:¥1(人民幣)
  • 規(guī)格:ACCUPRO 516-902-22
  • 發(fā)貨地:廈門(mén)
  • 品牌:
  • 最小起訂量:110
  • 誠(chéng)信商家
    會(huì)員級(jí)別:鉆石會(huì)員
    認(rèn)證類(lèi)型:企業(yè)認(rèn)證
    企業(yè)證件:通過(guò)認(rèn)證

    商鋪名稱:廈門(mén)紀(jì)揚(yáng)科技有限公司

    聯(lián)系人:葉小姐(小姐)

    聯(lián)系手機(jī):

    固定電話:

    企業(yè)郵箱:1094469569@qq.com

    聯(lián)系地址:廈門(mén)市翔安區(qū)鼓巖路1號(hào)華論國(guó)際1003

    郵編:361001

    聯(lián)系我時(shí),請(qǐng)說(shuō)是在線纜網(wǎng)上看到的,謝謝!

    商品詳情

      Contact Us
      ? To learn more about this offering visit
      http://www.ge-energy.com/training, contact your local

      GE
      Energy office or call 1-888-GE4-SERV or 540-378-3280.
      Trademarks:
      AF-300E, AF-300 G11, and AF-300 P11 are trademarks of

      GE Fuji Drives USA, Inc.
      American Express is a registered trademark of American

      Express Company.
      AV-300, AV-300i, DC-300, DV-300, EX2100, LS2100, Magne

      Blast, and SPEEDTRONIC
      are trademarks of General Electric Company, USA.
      Genius and VersaMax are registered trademarks of GE

      Fanuc Intelligent Platforms.
      HyperTerminal is a registered trademark of Hilgraeve,

      Inc.
      Dura-Bilt5 MV is a trademark of GE Toshiba Automation

      Systems LLC.
      Innovation Series and Limitamp are registered

      trademarks of General Electric Company, USA.
      MS-DOS and Windows are registered trademarks of

      Microsoft Corporation.
      Series 90 is a trademark of GE Fanuc Intelligent

      Platforms.
      Services and Spare Parts
      7
      7-24 Aftermarket Catalog www.geelectrical.com Prices

      and data subject
      to change without notice
      Services and Spare Parts
      Electrical Safety Training
      Overview
      GE Energy’s safety training team specializes in the

      development
      and delivery of world-class safety training programs

      with an
      emphasis on consistency, quality, and providing a

      practical learning
      experience for each student. Our professional safety

      instructors
      can help you realize these benefits by delivering

      safety training
      programs that provide insight and understanding into

      the risks
      inherent to electrical equipment and systems.
      Courses focus on electrical safety requirements as

      identified
      by OSHA in the General Industry Standards;

      requirements of the
      NFPA 70E Consensus Standards; and the requirements of

      the
      General Industry Lockout/Tagout (LOTO) Standard.

      Training
      courses can be offered at the customer’s site or at a

      GE Training
      Center. Electrical Safety & NFPA 70E for Qualified

      Individuals and
      LOTO require the student to achieve a passing score

      upon final
      examination. Certificates will be presented to

      students that
      successfully pass the course.
      Approach Boundaries – Shock Protection
      Applicability
      These courses are applicable to a broad range of

      industries
      where employees will encounter electrical equipment

      energized
      at greater than 50 volts.
      Available Courses
      Electrical Safety & NFPA 70E for Qualified Individuals
      Course Description: Required for individuals who face

      the risk of
      electrical shock, electrocution, or arc flash if the

      electrical system
      is not reduced to an electrically safe work condition.

      This course
      meets the electrical section of OSHA requirements –

      29 CFR
      1910.269, 29 CFR 1910.303 through 29 CFR 1910.308, and

      29
      CFR 1910.333.
      Course content includes: safety around electrical

      systems;
      affects of current on the body; Personal Protective

      Equipment
      (PPE) required for working near energized equipment;

      additional
      PPE that is required for applying LOTO to equipment

      that is to be
      de-energized; electrical power tool safety; grounding;

      bonding;
      static electricity and equipment potential hazards.

      (If purchased
      with a GE Arc Flash Hazard Study, this course will be

      customized
      to incorporate explanations of selected results

      detailing potential
      issues and recommendations.)
      Objectives
      ? Explain the fundamentals of electrical accidents
      ? Define proper procedures for identifying energized

      equipment
      and working on de-energized electrical equipment

      safely
      ? Explain how to recognize electrical safety hazards
      ? Recognize defined appropriate safe distances to

      energized
      equipment
      ? Explain static electricity and how it develops
      ? Explanation of “Equipotential” and Step Potential
      ? Selection of test equipment for identifying

      energized equipment
      ? Understand the limitations of test equipment
      ? Selection of PPE for individuals at risk of an

      electrical arc
      or explosion
      ? Proper method for identifying and applying

      electrical
      safety grounds
      ? Apply inspection guidelines for PPE and test

      equipment
      ? Understand hazard risk categories and their

      application
      in a number of situations
      NFPA 70E 130.2 Conductor
      Prohibited Space
      Restricted Space
      Restricted Approach
      Boundary
      Limited Space
      The Approach Boundaries relate
      to the voltage of the conductor
      Prohibited Approach
      Boundary
      Limited Approach
      Boundary
      Services and Spare Parts
      7
      Prices and data subject Aftermarket Catalog

      www.geelectrical.com 7-25
      to change without notice
      Services and Spare Parts
      Electrical Safety Training
      Length: 8 Hours
      Recommended Prerequisites. Prior knowledge of

      electrical
      equipment and systems, personal protective equipment

      and
      Lockout/Tagout training.
      Audience. Any individual who will be working near

      energized
      equipment and has the need to determine the degree and

      extent
      of the hazard and the personal protective equipment to

      perform
      a given task safely. Note: This course should not be

      provided to
      those individuals who do not have knowledge of the

      construction
      and operation of electrical equipment or the ability

      to determine
      the degree and extent of the hazard and the personal

      protective
      equipment to perform a given task safely.
      Lockout/Tagout
      This program is designed for workers who may be

      involved in
      Lockout/Tagout (LOTO) work as defined by the

      electrical section
      of OSHA requirements 29 CFR 1910.147. Lockout/Tagout

      training
      gives individuals the necessary steps to perform LOTO

      in the
      workplace. It is intended to give individuals the

      knowledge needed
      to prevent serious injury from the unexpected release

      or start-up
      of hazardous energy.
      Objectives
      ? Explain the meaning of Lockout/Tagout
      ? Define the requirements of a LOTO program
      ? Outline employee LOTO responsibilities
      ? Identify different types of energy sources
      ? Describe the basic Lockout/Tagout six-step process
      ? Define the term "Zero Energy State"
      Length: 4 Hours
      Recommended Prerequisites. None.
      Audience. Any individual who will be required to apply

      a lock, tag,
      or sign onto a LOTO system, or one who will be

      required to work
      on equipment, machinery, processes, or electric

      circuits.
      Fundamentals of NFPA 70E
      This course provides information and guidance for

      individuals
      who will have responsibilities for implementing,

      training and
      enforcing the safety-related work practices of the

      NFPA 70E
      consensus standard.
      Objectives
      ? Explain shock and arc flash hazard analysis
      ? Define requirements to train employees
      ? Outline employer and employee responsibilities
      ? Understand requirements for work/maintenance

      practices
      ? Explain procedures to select appropriate Personal
      Protective Equipment
      ? Define qualified individuals
      Length: 4 Hours
      Recommended Prerequisites. None
      Audience. Environment, Health and Safety

      professionals, plant
      personnel, and those individuals who will be

      implementing
      NFPA 70E requirements at their facility.
      To learn more about this offering, contact your GE

      Energy sales
      representative or visit www.ge-energy.com/training.
      imagination at work
      6/10 DEP-148A
      GE
      41 Woodford Avenue
      Plainville, CT 06062
      www.geelectrical.com
      ? 2010 General Electric Company
      IMPELLERS P566176-001
      IMPELLER WEARING RINGS P537994-001Voltage Rating

      Rating Product No. GO-5AC Drive Product No.
      0.33 0.25 NEMA1ACA2 緯軒機(jī)電110.00 6KGP23F25X9XXXA1
      0.5 0.37 NEMA1ACA2 緯軒機(jī)電110.00 6KGP23F50X9XXXA1
      1 0.75 NEMA1ACA2 緯軒機(jī)電110.00 6KGP23001X9XXXA1
      2 1.5 NEMA1ACA2 緯軒機(jī)電110.00 6KGP23002X9XXXA1Size 1

      Standard O/L 9000RSG1 緯軒機(jī)電87.00
      Size 1 Electronic O/L 9000RSG2 緯軒機(jī)電87.00
      O/L Reset Assembly Size 2,5 Standard O/L 9000RSG3 緯軒

      機(jī)電87.00
      Size 2,5 Electronic O/L 9000RSG4 緯軒機(jī)電87.00
      Size 3,4 Standard O/L 9000RSG5 緯軒機(jī)電87.00
      Size 3,4 Electronic O/L 9000RSG6 緯軒機(jī)電87.00
      Door Hinges Door Hinges 190B1013P1 緯軒機(jī)電9.00
      Power Pull Apart Terminal Block 50A 190B1691G1 緯軒機(jī)

      電84.00
      Terminal Block Din Rail Assembly 18 Points Max

      190B2070G6 緯軒機(jī)電309.00
      Terminal Blocks Terminal Block Din Rail Assembly 18

      Points Max w/ TB 190B2070G12 緯軒機(jī)電534.00
      Control TB 30A Male and Female 190B1692G1 緯軒機(jī)電

      45.00
      Wireway Covers Top 12" with hinges 110C1440G1 緯軒機(jī)電

      170.00 Wireway Covers Wireway Covers Top 18" with

      hinges 110C1440G2 緯軒機(jī)電204.00
      CPT 150VA, 480/120 Size 1 and 2 w/o Fuse Block

      9T58K0504G37 緯軒機(jī)電310.001
      Control Power Transformers CPT 300VA, 480/120 Size 1

      and 2 With Fuse Block 9T58K0507G38 緯軒機(jī)電390.001
      CPT 100VA, 480/120 Size 1 1/2X, Size 5 W/O Fuse Block

      MIC#B100-2989-5 緯軒機(jī)電240.00
      Standard Shelf 110C1059P1 緯軒機(jī)電144.00
      Shelf Grounding Bracket 270A1343G1 緯軒機(jī)電18.00
      Miscellaneous Bus Shutter Assembly 110C1783G1 緯軒機(jī)電

      346.00
      Vertical Bus Stab Covers 190B1215P1 緯軒機(jī)電9.00
      Wireway Knock Out Panel 190B1014P1 緯軒機(jī)電12.00
      Shelf Support - 72" High 110C1010G11 緯軒機(jī)電310.00
      Circuit Breaker/Starter Handles E and F Frame CB

      Vertical Handle Only 190B1704G1 緯軒機(jī)電120.00
      E and F Frame CB Horizontal Handle Only 190B1704G2 緯

      軒機(jī)電120.00
      6" EK06 緯軒機(jī)電120.002
      12" EK12 緯軒機(jī)電240.002
      18" EK18 緯軒機(jī)電490.00
      Filler Kits 24" EK24 緯軒機(jī)電505.00
      (Includes Shelf and Grounding Bracket) 30" EK30 緯軒機(jī)

      電575.00
      36" EK36 緯軒機(jī)電610.00
      42" EK42 緯軒機(jī)電640.00
      48" EK48 緯軒機(jī)電680.00
      Rear Cover Only 190B1007P9 緯軒機(jī)電114.00
      Rear Doors Only Rear Hinge Door Top Only 110C1466G9 緯

      軒機(jī)電132.00
      Rear Hinge Door Bottom Only 110C1466G21 緯軒機(jī)電132.00
      Rear Hinge Mounting Bracket (2 Per Section) 110C1464P1

      緯軒機(jī)電14.00
      6" High 110C1163G1 緯軒機(jī)電260.00
      12" High 110C1163G2 緯軒機(jī)電332.80
      18" High 110C1163G3 緯軒機(jī)電353.60
      24" High 110C1163G4 緯軒機(jī)電374.40
      30" High 110C1163G5 緯軒機(jī)電396.00
      Wire Trough Doors (4") 36" High 110C1163G6 緯軒機(jī)電

      416.00
      42" High 110C1163G7 緯軒機(jī)電426.40
      48" High 110C1163G8 緯軒機(jī)電426.40
      54" High 110C1163G9 緯軒機(jī)電457.60
      60" High 110C1163G10 緯軒機(jī)電478.40
      66" High 110C1163G11 緯軒機(jī)電499.20
      72" High 110C1163G12 緯軒機(jī)電572.00
      Muffin Fan 120V Only MUFFINFANG1 緯軒機(jī)電376.00
      Cooling Fans Tarzan Fan Only RMC#020169 緯軒機(jī)電

      1245.50
      Case Fan Assembly 110C1556G1 緯軒機(jī)電4012.00
      N3R Fan Assemblies Refer to Factory N/A
      6" 110C1240KKG1 緯軒機(jī)電166.00
      12" 110C1240KKG2 緯軒機(jī)電208.00
      18" 110C1240KKG3 緯軒機(jī)電240.00
      Blank Unit Door 24" 110C1240KKG4 緯軒機(jī)電250.00
      30" 110C1240KKG5 緯軒機(jī)電312.00
      36" 110C1240KKG6 緯軒機(jī)電343.20
      42" 110C1240KKG7 緯軒機(jī)電374.40
      48" 110C1240KKG8 緯軒機(jī)電416.00
      6 Unit Device Plate Only 110C1039P100 緯軒機(jī)電30.00
      Pilot Device Bracket 3 Unit Device Plate Only

      110C1089P100 緯軒機(jī)電30.00
      Bracket 190B1662P1 緯軒機(jī)電16.00
      600Amp Bus 110C1735G1SM 緯軒機(jī)電170.00
      Splice Kits 800Amp Bus 110C1735G4SM 緯軒機(jī)電250.00
      (Evolution to Evolution N1, N12 Only) 1200Amp Bus

      110C1735G7SM 緯軒機(jī)電280.00
      (Standard Tin Only) 2000Amp Bus 110C1735G12SM 緯軒機(jī)電

      700.00
      2500Amp Bus 110C1735G13SM 緯軒機(jī)電1700.00
      50Amp CSC#A50QS50 緯軒機(jī)電70.00NONE NN* 緯軒機(jī)電0.00
      RED LGT STD AE* 緯軒機(jī)電155.00
      RED LGT PUSH-TO-TEST (PTT) AF 緯軒機(jī)電250.00
      RED/GREEN LGT STD AS* 緯軒機(jī)電310.00
      RED/GREEN LGT PTT AT 緯軒機(jī)電500.00
      HAND/OFF/AUTO (H/O/A) SW. AN* 緯軒機(jī)電175.00
      H/O/A SW. RED LGT STD AB* 緯軒機(jī)電330.00
      H/O/A SW. RED LGT PTT AP 緯軒機(jī)電425.00
      H/O/A SW. R/G LGT STD AC* 緯軒機(jī)電485.00
      H/O/A SW. R/G LGT PTT AQ 緯軒機(jī)電675.00
      H/O/A STOP/START RED LGT STD AD 緯軒機(jī)電475.00
      H/O/A STOP/START RED LGT PTT AR 緯軒機(jī)電570.00
      STOP/START PB BN* 緯軒機(jī)電145.00
      STOP/START PB RED LGT STD BB* 緯軒機(jī)電300.00
      STOP/START PB RED LGT PTT BP 緯軒機(jī)電395.00
      STOP/START PB R/G LGT STD BC 緯軒機(jī)電455.00
      STOP/START PB R/G LGT PTT BQ 緯軒機(jī)電645.00
      OFF/ON SW. GN* 緯軒機(jī)電120.00
      OFF/ON SW. RED LGT STD GB* 緯軒機(jī)電275.00
      OFF/ON SW. RED LGT PTT GP 緯軒機(jī)電370.00
      OFF/ON SW. R/G LGT STD GC* 緯軒機(jī)電430.00
      OFF/ON SW. R/G LGT PTT GQ 緯軒機(jī)電620.00

    在線詢盤(pán)/留言
  • 0571-87774297