227 IEC 01(BV)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
導(dǎo)體種類
|
絕緣厚度規(guī)定值mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻
MΩ·km
|
1.5
1.5
2.5
2.5
4
4
6
6
10
10
16
25
35
50
70
95
120
150
185
240
300
400
|
1
2
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
|
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
|
3.3
3.4
3.9
4.2
4.4
4.8
4.9
5.4
6.4
6.8
8.0
9.8
11.0
13.0
15.0
17.0
19.0
21.0
23.5
26.5
29.5
33.5
|
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0050
0.0050
0.0040
0.0045
0.0035
0.0035
0.0032
0.0032
0.0032
0.0032
0.0030
0.0028
|
注:(1)按 GB/T3956-97規(guī)定:正常使用時,導(dǎo)體溫度最高為70℃。
(2)絕緣料應(yīng)采用PVC/C型聚氯乙烯混合物。
(3)平均外徑應(yīng)不大于表中規(guī)定的上限值。
一般用途單芯軟導(dǎo)體無護套電纜,如表3。
表3 227 IEC 02(RV)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻
MΩ·KM
|
1.5
2.5
4
6
10
16
25
|
0.7
0.8
0.8
0.8
1.0
1.0
1.2
|
3.5
4.2
4.8
6.3
7.6
8.8
11.0
|
0.010
, <, SPAN lang=EN-US style="FONT-SIZE: 9pt; FONT-FAMILY: 宋體; LETTER-SPACING: 0.6pt; mso-font-kerning: 0pt; mso-bidi-font-family: 宋體">0.009
0.007
0.006
0.0056
0.0046
0.0044
|
續(xù)表3 227 IEC 02(RV)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻
MΩ·KM
|
35
50
70
95
120
150
185
240
|
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
|
12.5
14.5
17.0
19.0
21.0
23.5
26.0
29.5
|
0.0038
0.0037
0.0032
0.0032
0.0029
0.0029
0.0029
0.0028
|
注:(1)按 GB/T3956-97規(guī)定:正常使用時,導(dǎo)體溫度最高為70℃。
(2)絕緣料應(yīng)采用PVC/C型聚氯乙烯混合物。
(3)平均外徑應(yīng)不大于表中規(guī)定的上限值。
內(nèi)部布線用導(dǎo)體溫度為70℃的單芯實心導(dǎo)體無護套電纜,如表4。
表4 227 IEC 05(BV)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻MΩ·km
|
0.5
0.75
1
|
0.6
0.6
0.6
|
2.4
2.6
2.8
|
0.015
0.012
0.011
|
注:(1)額定電壓300/500V。
(2)按GB/T3956-97規(guī)定:正常使用時,導(dǎo)體溫度最高為70℃。
(3)絕緣料應(yīng)采用PVC/C型聚氯乙烯混合物。
(4)平均外徑應(yīng)不大于表中規(guī)定的上限值。
內(nèi)部布線用導(dǎo)體溫度為70℃的單芯軟導(dǎo)體無護套電纜,如表5。
表5 227 IEC 06(RV)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻MΩ·km
|
0.5
0.75
1
|
0.6
0.6
0.6
|
2.6
2.8
3.0
|
0.013
0.011
0.009
|
注:(1)額定電壓300/500V。
(2)按GB/T3956-97規(guī)定:正常使用時,導(dǎo)體溫度最高為70℃。
(3)絕緣料應(yīng)采用PVC/C型聚氯乙烯混合物。
(4)平均外徑應(yīng)不大于表中規(guī)定的上限值。
內(nèi)部布線用導(dǎo)體溫度為90℃的單芯實心導(dǎo)體無護套電纜,如表6。
表6 227 IEC 07(BV—90)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻MΩ·km
|
0.5
0.75
1.0
1.5
2.5
|
0.6
0.6
0.6
0.7
0.8
|
2.4
2.6
2.8
3.3
3.9
|
0.015
0.013
0.013
0.011
0.009
|
注:(1)額定電壓300/500V。
(2)按GB/T3956-97規(guī)定:正常使用時,導(dǎo)體溫度最高為90℃。
(3)絕緣料應(yīng)采用PVC/E型聚氯乙烯混合物。
內(nèi)部布線用導(dǎo)體溫度為90℃的單芯軟導(dǎo)體無護套電纜,如表7。
表7 227 IEC 08(RV—90)型電纜的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm
|
平均外徑上限
mm
|
70℃時最小絕緣電阻MΩ·km
|
0.5
0.75
1.0
1.5
2.5
|
0.6
0.6
0.6
0.7
0.8
|
2.6
2.8
3.0
3.5
4.2
|
0.013
0.012
0.010
0.009
0.009
|
注:(1)額定電壓300/500V。
(2)按GB/T3956-97規(guī)定:正常使用時,導(dǎo)體溫度最高為90℃。
(3)絕緣料應(yīng)采用PVC/E型聚氯乙烯混合物。
固定布電線用輕型聚氯乙烯絕緣和護套電纜,如表8。
表8 227 IEC 10(BVV)型電纜的綜合數(shù)據(jù)
導(dǎo)體芯數(shù)和標稱截面mm2
|
導(dǎo)體種類
|
絕緣厚度規(guī)定值mm
|
內(nèi)護層厚度近似值mm
|
護套厚度規(guī)定值mm
|
平均外徑
|
70℃時最小絕緣電阻
MΩ·km
|
下限
mm
|
上限
mm
|
2*1.5
2*2.5
2*4
2×6
2×10
2×16
2×25
2×35
|
1
2
1
2
1
2
1
2
1
2
2
2
2
|
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
|
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.6
0.6
0.8
1.0
|
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.6
|
7.6
7.8
8.6
9.0
9.6
10.0
10.5
11.0
13.0
13.5
15.5
18.5
21.0
|
10.0
10.5
11.5
12.0
12.5
13.0
13.5
<, FONT style="FONT-SIZE: 15px; FONT-FAMILY: eWebEditor_Temp_Fon, tName">14.0<, /O:P>
16.5
17.5
20.0
24.0
|
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0052
0.0050
|
續(xù)表8 227 IEC 10(BVV)型電纜的綜合數(shù)據(jù)
導(dǎo)體芯數(shù)和標稱截面mm2
|
導(dǎo)體種類
|
絕緣厚度規(guī)定值mm
|
內(nèi)護層厚度近似值mm
|
護套厚度規(guī)定值mm
|
平均外徑
|
70℃時最小絕緣電阻
MΩ·km
|
下限
mm
|
上限
mm
|
3×1.5
3×2.5
3×4
3×6
3×10
3×16
3×25
3×35
4×1.5
4×2.5
4×4
4×6
4×10
4×16
4×25
4×35
5×1.5
5×2.5
5×4
5×6
5×10
|
1
2
1
2
1
2
1
2
1
2
2
2
2
1
2
1
2
1
2
1
2
1
2
2
2
2
1
2
1
2
1
2
1
2
1
2
|
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
0.7
0.7
0.8
0.8
0.8
0.8
0.8
0.8
1.0
1.0
|
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.6
0.8
0.8
1.0
0.4
0.4
0.4
0.4
0.4
0.4
0.6
0.6
0.6
0.6
0.8
1.0
1.0
0.4
0.4
0.4
0.4
0.6
0.6
0.6
0.6
0.6
0.6
|
1.2
1.2
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.6
1.6
1.2
1.2
1.2
1.2
1.4
1.4
1.4
1.4
1.4
1.4
|
8.0
8.2
9.2
9.4
10.0
10.5
11.5
12.0
14.0
14.5
16.5
20.5
22.0
8.6
9.0
10.0
10.0
11.5
12.0
12.5
13.0
15.5
16.0
18.0
22.5
24.5
9.4
9.8
11.0
11.0
12.5
13.0
13.5
14.5
17.0
17.5
|
10.5
11.0
12.0
12.5
13.0
13.5
14.5
15.5
17.5
19.0
21.5
26.0
29.0
11.5
12.0
13.0
13.5
14.5
15.0
16.0
17.0
19.0
20.5
23.5
28.5
32.0
12.0
12.5
14.0
14.5
16.0
17.0
17.5
18.5
21.0
22.0
|
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0052
0.0050
0.0044
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
0.0052
0.0050
0.0044
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0070
0.0065
|
續(xù)表8 227 IEC 10(BVV)型電纜的綜合數(shù)據(jù)
導(dǎo)體芯數(shù)和標稱截面mm2
|
導(dǎo)體種類
|
絕緣厚度規(guī)定值mm
|
內(nèi)護層厚度近似值mm
|
護套厚度規(guī)定值mm
|
平均外徑
|
70℃時最小絕緣電阻
MΩ·km
|
下限
mm
|
上限
mm
|
5×16
5×25
5×35
|
2
2
2
|
1.0
1.2
1.2
|
0.8
1.0
1.2
|
1.6
1.6
1.6
|
20.5
24.5
27.5
|
26.0
31.5
35.0
|
0.005 2
0.005 0
0.004 4
|
注:(1)導(dǎo)體種類按GB/T3956-97規(guī)定;正常使用時,導(dǎo)體最高溫度為70℃。
(2)絕緣應(yīng)采用PVC/C型聚氯乙烯混合物擠包;內(nèi)護層由非硫化型橡皮或塑料混合物組成;護套應(yīng)采用PVC/ST4型聚氯乙烯混合物擠包。
(3)額定電壓為300/500V。
聚氯乙烯絕緣扁形無護套電纜(軟線),如表9。
表9 227 IEC 42(RVB)型軟線的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度規(guī)定值
mm2
|
平均外形尺寸
|
70℃時最小絕緣電阻
ΜΩ·Km
|
下限
mm
|
下限
mm
|
0.5
0.75
|
0.8
0.8
|
2.5×5.0
2.7×5.4
|
3.0×6.0
3.2×6.4
|
0.016
0.014
|
注:(1)導(dǎo)體種類按GB/T3956-97規(guī)定;正常使用時,導(dǎo)體最高溫度為70℃。
(2)絕緣應(yīng)采用PVC/D型聚氯乙烯混合物擠包;在導(dǎo)體之間的絕緣兩邊應(yīng)有一凹槽,以便于分離絕緣線芯。
(3)額定電壓為300/300V。
聚氯乙烯(雙層)戶內(nèi)裝飾照明回路用軟線,如表10。
表10 227 IEC 43(SVR)型軟線的綜合數(shù)據(jù)
,
導(dǎo) 體
標稱截面
mm2
|
絕緣各層厚度最小值
mm
|
絕緣總厚度
最小值
mm
|
絕緣厚度
平均值
mm
|
平均外徑
上限
mm
|
70℃時最小絕緣電阻 ΜΩ·km
|
0.5
0.75
|
0.2
0.2
|
0.6
0.6
|
0.7
0.7
|
2.7
2.9
|
0.014
0.012
|
注:(1)導(dǎo)體種類按GB/T3956-97規(guī)定;正常使用時,導(dǎo)體最高溫度為70℃。
(2)絕緣應(yīng)采用PVC/D型聚氯乙烯混合物,絕緣由兩層組成,并用雙層同時擠包在導(dǎo)體上,絕緣的內(nèi)、外層塑料顏色應(yīng)有明顯反差,且全粘在內(nèi)層絕緣上,外層絕緣顏色優(yōu)選綠色。
(3)額定電壓為300/300V。
輕型聚氯乙烯絕緣護套軟線,如表11。
表11 227 IEC 52(RVV)型軟線的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度
規(guī)定值
mm
|
護套厚度
規(guī)定值
mm
|
平均外形尺寸
|
70℃時最小絕緣電阻
ΜΩ·Km
|
下限
mm
|
上限
mm
|
2×0.5
2×0.75
3×0.5
3×0.75
|
0.5
0.5
0.5
0.5
|
0.6
0.6
0.6
0.6
|
4.8
或
3.0×4.8
5.2
或
3.2×5.2
5.0
5.4
|
6.0
或
3.6×6.0
6.4
或
3.9×6.4
6.2
6.8
|
2×0.5
2×0.75
3×0.5
3×0.75
|
注:(1)導(dǎo)體種類按GB/T3956-97規(guī)定;正常使用時,導(dǎo)體最高溫度為70℃。
(2)絕緣應(yīng)采用PVC/D型聚氯乙烯混合物。圓形軟線,絕緣線芯應(yīng)絞合在一起;扁形軟線,則絕緣線芯應(yīng)平行放置。
(3)護套采用PVC/ST5型聚氯乙烯混合物。
(4)額定電壓為300/300V。
普通聚氯乙烯絕緣和護套軟電纜,如表12。表12 227 IEC 53(RVV)型軟線的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度
規(guī)定值
mm
|
護套厚度
規(guī)定值
mm
|
平均外形尺寸
|
70℃時最小絕緣電阻
ΜΩ·Km
|
下限
mm
|
上限
mm
|
2×0.75
2×1.0
2×1.5
2×2.5
3×0.75
3×1.0
3×1.5
3×2.5
4×0.75
4×1.0
4×1.5
4×2.5
|
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
0.6
0.6
0.7
0.8
|
0.8
0.8
0.8
1.0
0.8
0.8
0.9
1.1
0.8
0.9
0.9
1.1
|
6.0
或
3.8×6.0
6.4
7.4
8.9
6.4
6.8
8.0
9.6
6.8
7.6
8.0
10.5
|
7.6
或
5.2×7.6
8.0
9.0
11.0
8.0
8.4
9.8
12.0
8.6
9.4
11.0
13.0
|
2×0.75
2×1
2×1.5
2×2.5
3×0.75
3×1
3×1.5
3×2.5
4×0.75
4×1
4×1.5
4×2.5
|
續(xù)表12 227 IEC 53(RVV)型軟線的綜合數(shù)據(jù)
導(dǎo)體標稱截面
mm2
|
絕緣厚度
規(guī)定值
mm
|
護套厚度
規(guī)定值
mm
|
平均外形尺寸
|
70℃時最小絕緣電阻
ΜΩ·Km
|
下限
mm
|
上限
mm
|
5×0.75
5×1.0
5×1.5
5×2.5
|
0.6
0.6
0.7
0.8
|
0.9
0.9
1.1
1.2
|
7.4
8.3
10.0
11.5
|
9.6
10.0
12.0
14.0
|
0.011
0.010
0.010
0.009
|
注:(1)導(dǎo)體種類按GB/T3956-97規(guī)定;正常使用時,導(dǎo)體最高溫度為70℃。
(2)絕緣應(yīng)采用PVC/D型聚氯乙烯混合物。圓形軟線,絕緣線芯應(yīng)絞合在一起;扁形軟線,則絕緣線芯應(yīng)平行放置。
(3)護套采用PVC/ST5型聚氯乙烯混合物。
(4)額定電壓為300/300V。
|