商鋪名稱:廈門興銳嘉進(jìn)出口有限公司
聯(lián)系人:劉錦玉(小姐)
聯(lián)系手機(jī):
固定電話:
企業(yè)郵箱:3005393110@qq.com
聯(lián)系地址:廈門市思明區(qū)呂嶺路1733號創(chuàng)想中心20樓
郵編:361000
聯(lián)系我時(shí),請說是在線纜網(wǎng)上看到的,謝謝!
產(chǎn)品描述
IC200MDL740D是一個(gè)可用的通用標(biāo)志VIe體系控制器。這是一個(gè)后的電子轉(zhuǎn)速體系發(fā)布的通用電氣工業(yè)氣體和蒸汽渦輪機(jī)的辦理。UCSB IS420UCSBH4A是五、控制器中使用馬克競爭體系。 這是一個(gè)四核提供高性能的控制器和可靠性。單位是建立在操作體系QNX的中微子一個(gè)1066 MHz英特爾EP80579微處理器上運(yùn)行。這個(gè)體系使用控制塊言語與布爾邏輯繼電器梯形圖的格式。 這種格式支持布爾邏輯以及簽署的16位和32位無符號整數(shù)以及32位和64位浮點(diǎn)編程。
IS420UCSBH4A重2.4磅,是專為操作在環(huán)境溫度-22 + 149華氏度之間。 通用電氣手動geh - 6721卷1將會有更多的信息關(guān)于這個(gè)設(shè)備的技能要求和環(huán)境的限制。
IS420UCSBH4A能夠支持互操作的冗余裝備和不同的平臺類型一起作業(yè)在冗余設(shè)置。這意味著如果一個(gè)控制器設(shè)置發(fā)生失敗,運(yùn)營商能夠替代它與相同或不同的控制器類型支持流程正在運(yùn)行,沒有工廠的損失控制。IS420UCSBH4A兼容UCSCH2A控制器。說明如何替換一個(gè)控制器能夠找到一組冗余在通用電氣出版物geh - 6700或geh - 6703。
★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★★
主營產(chǎn)品,備件供應(yīng),充足庫存
Foxboro(?怂共_):I/A Series系統(tǒng),F(xiàn)BM全系列(現(xiàn)場輸入/輸出模塊)
順序控制、梯形邏輯控制、事故追憶處理、數(shù)模轉(zhuǎn)換、輸入/輸出信號處理、
數(shù)據(jù)通信及處理等。
Westinghouse(西屋):1C31系列DCS系統(tǒng)、CPU、OVATION系統(tǒng)、WDPF系統(tǒng)、
WEStation系統(tǒng)備件。
Triconex(英維思):冗余容錯(cuò)控制系統(tǒng)、基于三重模件冗余(TMR)結(jié)構(gòu)的現(xiàn)代化的容錯(cuò)控制器。
EMERSON(艾默生):模塊、卡件、驅(qū)動器等各類備件。
XYCOM:XVME系列
Bently(本特利):3500/3300系統(tǒng)。
Rockwell(羅克韋爾):ICS系統(tǒng)。
ABB:PM全系列DCS系統(tǒng)、IGCT高壓變頻器系列、工業(yè)機(jī)器人備件DSQC系列、INFI 90等。
Bailey(貝利):BRC系列DCS系統(tǒng)等。
Allen-Bradley:1756、1785、1771、1746全系列系統(tǒng)等。
Yokogawa(橫河):CP系列等。
Honeywell(霍尼韋爾):TK/TC/CC系統(tǒng)等。
Reliance(瑞恩):57C系列等。
Schneider(施耐德):140系列處理器、控制卡、電源模塊等。
Modicon(莫迪康):AS系列PLC系統(tǒng)備件。
Siemens(西門子):6ES5/6ES7414/6ES7415/6ES7416系列PLC系統(tǒng)備件、
Siemens MOORE,Siemens Simatic C1,Siemens數(shù)控系統(tǒng)等。
Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
XYCOM:I/O、VME板和處理器等。
GE(通用電氣):IC698/IC697全系列PLC系統(tǒng)、模塊、卡件、驅(qū)動器等各類備件。
Yaskawa(安川):伺服控制器、伺服馬達(dá)、伺服驅(qū)動器。
Bosch Rexroth(博世力士樂):Indramat,I/O模塊,PLC控制器,驅(qū)動模塊等。
Woodward(伍德沃德):SPC閥位控制器、PEAK150數(shù)字控制器。
How to choose between PLC and DCS depends on the specific project and plant type. Because of different applications, the requirements of the control system are also different.
In addition to some basic criteria, we must also consider the installation, scalability, maintenance and other factors. Sometimes, one choice is very suitable for a factory, and in another case it may not be. Therefore, the more factors considered in the selection of control system, the more conducive to the realization of short-term and long-term goals.
At present, although PLC system may be the most cost-effective for small equipment, DCS system provides more economical scalability and is more likely to obtain higher initial return on investment.
PLC is suitable for discrete production, generally composed of separate production devices, mainly used to complete the assembly of components, such as labeling, filling or grinding. DCS is suitable for process manufacturing. Automated systems are often used to produce by recipe rather than by piece in a continuous and batch manner. Large scale continuous processing equipment, such as refineries and chemical plants, all use DCS system. Mixed application usually uses PLC and DCS at the same time.
■ process scale:
Small system (<300 i / o points) may have less budget, so plc is more suitable. dcs has a global database, which is easier to manage and upgrade, and can play a more important role in large factory applications.
■ upgrade plan:
PLC system can be selected for small-scale industrial process, but if the process needs to be expanded or upgraded, more PLC hardware and database need to be added, and independent maintenance is needed. This process is time-consuming and laborious, and prone to errors. At this time, DCS is more suitable. As DCS is easier to upgrade, it can also manage users&#39; trust from the central hub, so it is easier for later maintenance.
Integration requirements:
For stand-alone device, PLC is the ideal choice. When the factory configures multiple PLCs, it will produce the requirement of interconnection. This is generally difficult to implement because it is usually necessary to map data using communication protocols. Especially when the user needs to change, once a PLC system is changed, the two PLCs may not communicate normally. DCS does not need mapping, configuration change is just a simple process, the controller is the system&#39;s own.
興銳嘉主營產(chǎn)品:
GE庫存相關(guān)型號:
IC697ALG230
IC697ALG320
IC697ALG440
IC697ALG441
IC697BEM711
IC697BEM713
IC697BEM721
IC697BEM731
IC697BEM733
IC697BEM741
IC697BEM761
IC697CGR772
IC697CGR935
IC697CHS750
IC697CHS770
IC697CHS771
IC697CHS782
IC697CHS783
IC697CHS790
IC697CHS790RR
IC697CHS790xSV
IC697CHS791
IC697CMM711
IC697CMM712
IC697CMM721
IC697CMM741
IC697CMM742
IC697CPM790
IC697CPU731
IC697CPU780
IC697CPU788
IC697CPU789
IC697CPX772
IC697CPX782
IC697CPX928
IC697CPX935
IC697CSE784
IC697CSE925
IC697GDH701
IC697GDS701
IC697HSC700
IC697LBR701