電機(jī)電抗器 西門子6SL3000-2BE32-1AA0
電機(jī)電抗器 西門子6SL3000-2BE32-1AA0
產(chǎn)品價(jià)格:¥432(人民幣)
  • 規(guī)格:6SL30002BE321AA0
  • 發(fā)貨地:上海
  • 品牌:
  • 最小起訂量:1件
  • 誠信商家
    會(huì)員級(jí)別:鉆石會(huì)員
    認(rèn)證類型:企業(yè)認(rèn)證
    企業(yè)證件:通過認(rèn)證

    商鋪名稱:上海斌勤電氣技術(shù)有限公司

    聯(lián)系人:康奎(先生)

    聯(lián)系手機(jī):

    固定電話:

    企業(yè)郵箱:192061030@qq.com

    聯(lián)系地址:上海市松江區(qū)三新北路1800弄(松江電子商務(wù)園區(qū))

    郵編:201501

    聯(lián)系我時(shí),請(qǐng)說是在線纜網(wǎng)上看到的,謝謝!

    商品詳情

      電機(jī)電抗器 西門子6SL3000-2BE32-1AA0

      SINAMICS/MICROMASTER PX 電機(jī)電抗器用于 3AC 380-480V,50/60Hz,210A AC Drive/功率模塊/ 電機(jī)模塊

      概述

      Output reactor

      Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.

      Owing to the high rates of voltage rise of the fast-switching IGBTs, the capacitance of long motor cables reverses polarity very quickly with every switching operation in the inverter. As a result, the inverter is loaded with additional current peaks of substantial magnitude.

      Output reactors reduce the magnitude of these additional peaks because the cable capacitance reverses polarity more slowly across the reactor inductance, thereby attenuating the amplitudes of the current peaks.

      When using output reactors, the following should be observed:

      • Max. permissible output frequency 150 Hz
      • Max. permissible pulse frequency 4 kHz
      • The output reactor must be installed as close as possible to the Power Module

      Two output reactors are to be provided to increase the permissible cable lengths.

      When connecting the Power Modules to IT networks, the use of an output reactor is recommended to avoid an overcurrent shutdown in the event of a ground fault.

      集成

      Available optional output reactors

       

      Frame size

       

      FSD

      FSE

      FSF

      PM240P?2 Power Module

      Available output reactors

       

       

       

      • 400 V versions

      • 690 V versions


      技術(shù)規(guī)范

      Line voltage 380 ... 480 V 3 AC

      Output reactor

       

      6SE6400-3TC07-5ED0

      6SE6400-3TC14-5FD0

      6SL3000-2BE32-1AA0

      6SL3000-2BE32-6AA0

      Rated current

      A

      90

      178 1)

      210

      260

      Power loss

      kW

      0.27

      0.47

      0.49

      0.5

      Connection to the Power Module

       

      Flat connector for M6 screw

      Flat connector for M8 screw

      Flat connector for M10 screw

      Flat connector for M10 screw

      Motor connection

       

      Flat connector for M6 screw

      Flat connector for M8 screw

      Flat connector for M10 screw

      Flat connector for M10 screw

      PE connection

       

      M6 screw

      M8 screw

      M8 screw

      M8 screw

      Cable length, max.

      between output reactor and motor

       

       

       

       

       

      • Shielded

      m (ft)

      200 (656)

      200 (656)

      300 (984)

      300 (984)

      • Unshielded

      m (ft)

      300 (984)

      300 (984)

      450 (1476)

      450 (1476)

      Dimensions

       

       

       

       

       

      • Width

      mm (in)

      270 (10.6)

      350 (13.8)

      300 (11.8)

      300 (11.8)

      • Height

      mm (in)

      248 (9.76)

      321 (12.6)

      285 (11.2)

      315 (12.4)

      • Depth

      mm (in)

      209 (8.23)

      288 (11.3)

      257 (10.1)

      277 (10.9)

      Degree of protection

       

      IP20

      IP20

      IP00

      IP00

      Weight, approx.

      kg (lb)

      27 (59.5)

      57 (126)

      60 (132)

      66 (146)

      Suitable for
      PM240P-2 Power Modules

      Type

      6SL3210-1RE24-5 . L0
      6SL3210-1RE26-0 . L0
      6SL3210-1RE27-5 . L0

      FSE:
      6SL3210-1RE28-8 . L0
      6SL3210-1RE31-1 . L0

      FSF:
      6SL3210-1RE31-5 . L0
      6SL3210-1RE31-8 . L0

      6SL3210-1RE32-1 . L0

      6SL3210-1RE32-5 . L0

      • Frame size

       

      FSD

      FSE/FSF

      FSF

      FSF


      1) On the rating plate of the reactor, the current is specified according to the duty cycle for high overload (HO). This is lower than the current specified according to the duty cycle for low overload (LO) of the Power Module.

      Line voltage 500 ... 690 V 3 AC

      Output reactor

       

      6SL3000-2AH31-0AA0

      6SL3000-2AH31-5AH0

      Rated current

      A

      100

      150

      Power loss

      kW

      0.3

      0.34

      Connection to the Power Module

       

      Flat connector for M10 screw

      Flat connector for M10 screw

      Motor connection

       

      Flat connector for M10 screw

      Flat connector for M10 screw

      PE connection

       

      M6 screw

      M6 screw

      Cable length, max.

      between output reactor and motor

       

       

       

      • Shielded

      m (ft)

      300 (984)

      300 (984)

      • Unshielded

      m (ft)

      450 (1476)

      450 (1476)

      Dimensions

       

       

       

      • Width

      mm (in)

      270 (10.6)

      270 (10.6)

      • Height

      mm (in)

      248 (9.76)

      248 (9.76)

      • Depth

      mm (in)

      200 (7.87)

      200 (7.87)

      Degree of protection

       

      IP00

      IP00

      Weight, approx.

      kg (lb)

      25 (55.1)

      25.8 (56.9)

      Suitable for
      PM240P-2 Power Modules

      Type

      6SL3210-1RH28-0 . L0
      6SL3210-1RH31-0 . L0

      6SL3210-1RH31-2 . L0
      6SL3210-1RH31-4 . L0

      • Frame size

       

      FSF

      FSF

      電機(jī)電抗器 西門子6SL3000-2BE32-1AA0

    在線詢盤/留言
  • 0571-87774297